5% (87–99%) ± 3 1% in the AP-PA field plans The mean dose to the

5% (87–99%) ± 3.1% in the AP-PA field plans. The mean dose to the intestines located in the lumbar radiotherapy fields was 66.2% (58–78%) ± 5.1% in the ICRUrp single field plans, 73.1% (64–88%) ± 6.2% in the IBMCrp single field plans and 90.8% (82–99%) ± 3.7% in the AP-PA fields plans. The mean doses to the esophagus and intestines were DZNeP price higher in the AP-PA field plans than in the single posterior field plans (p < 0.001). Dose ranges to the medulla spinalis for all plans

are shown in Table 2. The mean doses to the medulla spinalis were lower in the AP-PA field plans than in the single posterior field plans (p < 0.001).In all IBMCrp single field plans, maximum doses to the medulla spinalis were greater than 115% of the prescribed dose and in 22 of 45 (49%) plans AZD5582 datasheet the maximum doses were greater than 120% of the prescribed dose. In only 4 ICRUrp single field plans did the medulla spinalis receive a dose greater than 115% of the prescribed dose. In the AP-PA field plans, none of the doses to the medulla spinalis exceeded 106% of prescribed dose. Table 2 The mean percentages of minimum, maximum and mean medulla spinalis doses ± standard deviation for all plans   Mean dose (range) % ± SD   Single field-ICRUrp Single field-IBMCrp Two opposed fields Minimums 94.2 (85–102) ± 3.0 103.4 (96–109) ± 3.3 96.2 (94–101) ± 1.5 Maximums 108.8 (101–118) ± 3.6 120.1 (115–129) ± 3.5 103.2 (101–106)

± 1.4 Means 102 (95–112) ± 3.1 112.7 (107–117) ± 2.3 100.3 (98–104) ± 1.3 ICRUrp, the International Commission on Radiation Units and Measurements reference BVD-523 mw point; IBMCrp, the International Bone Metastasis Consensus Working Party reference

point; SD, standard deviation. Discussion The results of the present study showed that neither IBMCrp nor the ICRUrp single posterior field plans accomplished the ICRU Report 50 recommendations for dose distribution, while the AP-PA field plans achieved the intended dose ranges and homogeneity. The ICRU Report 50 recommends selecting a reference point that is clinically relevant and representative of the dose distribution throughout the PTV, where the dose can be accurately determined and where there is no large dose gradient [2]. The point located at the center or central part of the PTV generally fulfills these requirements and is recommended as the ICRU reference point (ICRUrp). mafosfamide While a homogeneous dose within 95% to 107% of the prescribed dose is recommended for the target volume, a variation of ± 10% from the prescribed dose is widely used in clinical practice and was used in the present study for AP-PA field plans [2]. Thoracic and lumbar spinal irradiation is performed either with a single posterior field or two opposed AP-PA fields [4]. The International Bone Metastasis Consensus Working Party recommends dose prescriptions to the mid-vertebral body for single-posterior fields and including at least one vertebral body above and below the involved vertebra(e) in the treatment volumes [3].

Comments are closed.