The temperature variation during in-field sample storage and dela

The temperature variation during in-field sample storage and delayed processing Ribociclib cell line did not significantly interfere with the detection of anti-HAV antibodies among oral samples when compared to the serum results. Sample storage at temperatures of 2–8 °C caused

no significant changes during the first 180 days after collection. However, at day 210, a decrease of one level on the colorimetric scale for reactive samples was observed, but the qualitative results remained the same. This stability should be considered in an epidemiological scenario in which there is no refrigeration, in developing countries that can have large and difficult to accommodate variations in temperature [28], or when samples are sent to the laboratory by mail service [23]. The collection methodology and sample preservation by the use of stabilizers in the ChemBio® device were considered an important strategy to avoid the problems of rapid antibody degradation during storage as reported by Gröschl and colleagues [26] for other collection devices. In this study, we observed that this preservation was MK0683 supplier sufficient to increase the stability of the sample. Thus, these results showed

that the ChemBio® device is suitable for vaccination and epidemiological surveillance in difficult-to-access areas because freezing is not required for sample storage. Oral fluid samples collected with the ChemBio®, OraSure® and Salivette® devices provided qualitative results that were sufficient for detecting anti-HAV antibodies under optimal conditions. However, the ChemBio® device had the best performance in the optimization panel, and the stability of samples collected with this device demonstrated that this device was most appropriate for a surveillance scenario. Moreover, oral fluid can be used to detect low-level, specific antibody levels in vaccinated individuals,

although the choice of the appropriate collection device is essential to evaluate HAV antibodies in difficult-to-access areas. from Oral fluid was used to demonstrate that it is possible to collect this clinical specimen when ideal storage conditions are not available, which is indispensable to determining the epidemiological profile of the disease and selecting age groups for vaccination. Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ) and Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq). “
“The authors regret that Table 2 of the above article contained errors. The correct version of Table 2 is reproduced below. The conclusions of this article remain unchanged. “
“Studies suggest that even patients vaccinated against tetanus and with antibody levels considered protective may acquire tetanus, depending on the immune status of the host and amount of tetanus neurotoxin produced by Clostridium tetani [1] and [2].

Comments are closed.