Two-dimensional high-performance

Two-dimensional high-performance

NVP-AUY922 liquid chromatography-mass spectrometry analysis Trypsinized peptides with or without iTRAQ label were separated in the first dimension using an Agilent 1100 Series HPLC system (Agilent Technologies, Wilmington, DE). Samples were injected onto a C18 X-Terra column (1 × 100 mm, 5 μm, 100 Å; Waters Corporation, Milford, MA, USA) and eluted with a linear water-acetonitrile gradient (20 mM ammonium formate, pH 10, in both eluents A and B, 1% acetonitrile/min, 150 μL/min flow rate). A concentrated 200 mM solution of ammonium formate at pH 10 was prepared as described Napabucasin by Gilar et al.[43]. Buffers A and B for first-dimension separation were prepared by a 1/10 dilution of this concentrated buffer with water and acetonitrile,

respectively. Fifty 1-min fractions were collected (roughly 6.6 μg/fraction). Samples were concatenated (fraction 1 and 31, 2 and 32, etc.) into a total of 25 fractions as described by Dwivedi et al.   [44]. Each was lyophilized and re-suspended in 100 μL of 0.1% formic acid. A splitless nanoflow Tempo LC system (Eksigent, Dublin, CA, USA) with 20 μL sample injection via a 300 μm × 5 mm PepMap100 precolumn and a 100 μm × 150 mm analytical column packed with 5 μm Luna C18(2) (Phenomenex, Torrance, CA) was used in the second-dimension separation prior to tandem MS analysis. Both eluents A (2% acetonitrile in water) and B (98% acetonitrile) contained 0.1% formic acid

as ion-pairing modifier. A 0.33% acetonitrile/min linear gradient (0-30% B) was used for peptide elution, providing a total 2 hour run time per fraction in the second dimension. Mass spectrometry A QStar Elite mass spectrometer (Applied Biosystems, Foster City, CA) was used in standard MS/MS data-dependent acquisition mode with a nano-electrospray ionization source. The 1 s survey MS spectra were collected (m/z 400–1500) Suplatast tosilate followed by three MS/MS measurements on the most intense parent ions (80 counts/s threshold, +2 to +4 charge state, m/z 100–1500 mass range for MS/MS), using the manufacturer’s “smart exit” settings and iTRAQ settings. Previously targeted parent ions were excluded from repetitive MS/MS acquisition for 60 s (50 mDa mass tolerance). Database search, protein identification, and statistical analysis Raw spectra WIFF files of unlabeled peptides were treated using standard CFTRinh-172 research buy script (Analyst QS 2.0) to generate text files in Mascot Generic File format (MGF) [45] and ProteoWizard to generate mzML files [46].

Comments are closed.